RADYASYON İZLEME SİSTEMİ İÇİN BİLGİSAYAR PROGRAMI: RAMOS

Mehmet BAYBURT 1 , Sevil BAYBURT 2 , Onur KAHVECİ 3

Bu çalışmada, nükleer laboratuarlarda kullanılan radyasyon izleme sistemleri için bir bilgisayar yazılımı geliştirilmiştir. Radyasyon laboratuvarlarının art ortamlarının izlenmesinde çeşitli detektör sistemleri kullanılmaktadır. Çalışmamızda, bir G-M detektör sisteminden gelen veriler Visual Basic dili kullanılarak yazılan program (RAMOS)aracılığı ile değerlendirilmekte ve saklanmaktadır. Böylece, radyasyon laboratuvarlarının art ortam seviyelerini kontrolü için bir veri tabanı elde edilecektir. Kablolu sistemler için geliştirilen program, kablosuz detektör sistemleri için de bir temel oluşturmaktadır. Program (RAMOS), bir G-M detektör sistemi kullanılarak test edilmiştir.

Keywords
RADYASYON, ART ORTAM İZLEME, VBASIC PROGRAMLAMA, DEDEKTÖR, LABORATUVAR,

COMPUTER PROGRAM FOR RADIATION MONITORING SYSTEM: RAMOS

Mehmet BAYBURT 1 , Sevil BAYBURT 1 , Onur KAHVECİ 1

In this study, a new computer program is developed a computer program for a computer controlled radiation monitoring system nuclear laboratories. Various detector systems are used for monitoring the background radiation level of the radiation laboratories. In our study, The data obtained from a G-M detector system are evaluated and stored using radiation monitoring system software (ramos) which is written visual basic programming language. A database is to be obtained for controlling the background radiation level of the radiation laboratories. Computer software developing for cable system is also to form the basis for the use of wireless detector systems. RAMOS were tested using a GM detector system.

Keywords
RADIATION, BACKGROUND MONITORING, VBASIC PROGRAMMING, DETECTOR, LABORATORY,