YUMUŞAK BETONARME ÇELİĞİNİN BETON BOŞLUK SUYU VE NaCl ÇÖZELTİSİ İÇERİSİNDE KOROZYON DAVRANIŞININ İNCELENMESİ

Mahmut AYTEKİN1 , Hadaa PEHLİVAN2

Betonarme yapı sistemi, çok farklı çevresel etkiler altında kaldığı için, beton ve donatı açısından önemli dayanıklılık sorunlarını da beraberinde getirmektedir [1]. Korozyon çelik konstrüksiyonlu yapılarda kaçınılmazdır. Ancak etkileri ve sonuçları etkin bir koruma sağlayarak en aza indirilebilir [2]. Çalışmada beton boşluk suyu içerisine sırasıyla %0.06, %0.09, %0.12, %0.15’ lik konsantrasyonlarda NaCl eklenerek hazırlanan çözelti içerisinde yumuşak betonarme çeliğinin korozyon davranışı incelenmiştir. Elektrokimyasal ölçümler 3 elektrot yöntemi kullanılarak yapılmıştır. Bu ölçümler ile yumuşak betonarme çeliğini açık devre potansiyelleri, Nyquist eğrileri ve Tafel eğrileri elde edilerek incelenmiş ve sonuçları oransal olarak kıyaslanmıştır. Beton boşluk suyu ve beton boşluk suyuna farklı konsantrasyonlarda sırasıyla eklenen %0.06, %0.09, %0.12, %0.15’ lik NaCl’ nin yumuşak betonarme çeliği üzerindeki etkisi elektrokimyasal yöntemlerle incelendiğinde; beton boşluk suyu içerisindeki NaCl miktarı arttıkça betonarme çeliğinin korozyon akım yoğunluğunun arttığı görülmüştür.

Keywords
Beton, Beton Boşluk Suyu, Korozyon, Yumuşak Betonarme Çeliği, Dayanıklılık,

INVESTIGATION OF CORROSION BEHAVIOR OF MILD REINFORCED CONCRETE STEEL IN CONCRETE PORE WATER AND NaCl SOLUTION

Mahmut AYTEKİN1 , Hadaa PEHLİVAN2

Reinforced concrete structure system can be used under a wide range of environmental influences and also brings significant durability problems in terms of concrete and reinforcement [1]. Corrosion is inevitable in steel construction structures. However, its effects and results can be minimized by providing effective protection [2]. In the study, the corrosion behavior of mild reinforced concrete steel in solution prepared by adding NaCl at %0.06, %0.09, %0.12 and %0.15 concentrations in concrete pore water, respectively. Electrochemical measurements were made using 3 electrode method. With these measurements, the open circuit potentials of the mild reinforced concrete steel, Nyquist curves and Tafel curves were investigated and the results were compared proportionally. When the effects of %0.06, %0.09, %0.12 and %0.15 NaCl on the mild reinforced concrete steel were investigated by electrochemical methods, respectively, added to the concrete pore water at different concentrations. It was observed that as the amount of NaCl in the concrete pore water increased, the corrosion current density increased in reinforced concrete steel.

Keywords
Concrete, Concrete Pore Water, Corrosion, Mild Reinforced Concrete Steel, Durability,

Details
   

Authors

Mahmut AYTEKİN (1) (Corresponding Author)

Kilis 7 Aralık University
mahmutaytekin@kilis.edu.tr | 0000-0002-2646-9080

Hadaa PEHLİVAN (2)

hadaantaban@kilis.edu.tr | 0000-0000-0000-0075

Supporting Institution

:

Project Number

:

Thanks

:
References
[1] Yiğiter, H., (2008). Betonarme Donatısında Klorid Korozyonu Gelişiminin Elektrokimyasal Yöntemlerle Belirlenmesi. Doktora Tezi. İzmir: Dokuz Eylül Üniversitesi Fen Bilimleri Enstitüsü.