YAYINIMLI SOĞURMALI SOĞUTMA SİSTEMİNDE FARKLI DIŞ ORTAM SICAKLIKLARININ PERFORMANSA ETKİSİ

Dogu CAMUR 1 , Engin ÖZBAS 2

Bu çalışmada, imal edilen Yayınımlı Soğurmalı Soğutma sisteminin 2 farklı dış ortam sıcaklığında (14°C ve 25°C)soğutma performansı karşılaştırılmıştır. Deneyler sırasında her bir dış ortam sıcaklığı için; iç ortam sıcaklığı, buharlaştırıcı yüzey sıcaklığı ve kılcal boru çıkış sıcaklığı ölçülmüş, bu değerler doğrultusunda REFPROP programından elde edilen verilerle her iki çalışma koşulu için sisteme ait soğutma tesir katsayıları (STK) hesaplanmıştır. Çalışma sonucunda, dış ortam sıcaklığın 14°C olduğu çalışma koşulunda buharlaştırıcı yüzeyi ve iç ortam sıcaklığının daha düşük olduğunu belirlenmiştir. 14°C de STK; 0,3584 kütlesel debi; 2,2914x10-5 iken 24°C de STK; 0,3469 debi; 2,2884x10-5 olarak bulunmuştur.

Keywords
YSS , Soğutma, STK , Amonyak, Su ,

EFFECT TO PERFORMANCE OF DIFFERENT OUTDOOR TEMPERATURES IN THE ABSORPTION REFRIGERATION SYSTEM

Dogu CAMUR 1 , Engin ÖZBAS 1

In this study, the cooling performances of 2 different outdoor temperatures(14 C 25 C)of a manufactured absorption refrigeration system are compared. During the experiment, inside ambiance temperature, evaporator surface temperature, capillary tube exit temperature are measured for each of the outdoor temperatures.In the direction of these values and after obtaining the datas from REFROP program ,coefficient of performances for each operating condition of the system are calculated. As a result of this study, It is determined that evaporator surface temperature and inside ambiance temperature are lower while the outside temperature is 14 C.At the temperature of 14 °C; Coefficient of performance is 0,3584, mass flow is 2.2914x10-5. At the temperature of 24 °C; Coefficient of performance is 0,3469, mass flow is 2,2884x10-5.

Keywords
DAR , Refrigeration , COP , Ammonia , Water,