• icon+90(533) 652 66 86
  • iconnwsa.akademi@hotmail.com
  • icon Fırat Akademi Samsun-Türkiye

Article Details

  • Article Code : NWSA-3660-2039
  • Article Type : Araştırma Makalesi
  • Publication Number : 1A0139
  • Page Number : 182-189
  • Doi : 10.12739/
  • Abstract Reading : 1479
  • Download : 151
  • Share :

  • PDF Download

Issue Details

  • Year : 2011
  • Volume : 6
  • Issue : 1
  • Number of Articles Published : 49
  • Published Date : 1.01.2011

Cover Download Context Page Download
Engineering Sciences

Serial Number : 1A
ISSN No. : 1308-7231
Release Interval (in a Year) : 4 Issues

LABORATUVAR İÇ AYDINLATMASININ PLC İLE OTOMASYONU: MARMARA ÜNİVERSİTESİNDE BİR UYGULAMA

Hayrettin Toylan 1 , Reşit Erçetin 2

Bu çalışmanın amacı, Marmara Üniversitesi Teknik Eğitim Fakültesi Aydınlatma laboratuvarında, gelişen aydınlatma programları ve otomasyon sistemleri yardımıyla optimal enerji tüketimi sağlayarak aydınlatma otomasyonu dizayn ve geliştirilmesidir. Bilgisayar aydınlatma programı(Dialüx) ile tipi ve konumu belirlenen lambalar, Programlanabilir Lojik Kontrolör (PLC) vasıtasıyla kademeli olarak kontrol edilmektedir. Bu kontrol yardımıyla lambaların açma kapama durumları, gün içerisinde gün ışığının değişimine bağlı olarak belirlenmiştir. Sonuç olarak geleneksel method olan manuel kontrollü aydınlatma sistemi ile bu çalışmadaki otomasyon sistemi mukayese edilmiş dikkate değer bir enerji tasarrufunun elde edildiği gözlenmiştir.

Keywords
Enerji Tasarufu, Aydınlatma Otomasyonu, Aydınlatma, Aydınlatma Programı, PLC,

AUTOMATION OF THE LABORATORY INDOOR LIGHTING BY MEANS OF PLC: AN APPLICATION IN MARMARA UNIVERSITY

Hayrettin Toylan 1 , Reşit Erçetin 1

The aim of this study is to design and develop lighting automation with the help of developing lighting programmes and automation systems using optimal energy use at Marmara University Technical Education Faculty Laboratory. The lamps that are determined in types and positions by computer Lighting programme (DIALUX) are controlled by PLC (Programmable Logic Control) step by step. With the help of this control system the on/off of the lamps are determined depending on the day light amount changes. As a conclusion, illimunation systems manually controlled and the automation system in this study are compared and a noticeable profit of energy is observed.

Keywords
Energy Saving, Lighting Automation, Illumination, Lighting Programme, PLC,

Details
   

Authors

Hayrettin Toylan (1) (Corresponding Author)

hayrettintoylan@kirklareli.edu.tr

Reşit Erçetin (2)

rercetin@marmara.edu.tr

Supporting Institution

:

Project Number

:

Thanks

:
References