• icon+90(533) 652 66 86
  • iconnwsa.akademi@hotmail.com
  • icon Fırat Akademi Samsun-Türkiye

Article Details

  • Article Code : NWSA-6401-2872
  • Article Type : Araştırma Makalesi
  • Publication Number : 1A0340
  • Page Number : 39-53
  • Doi : 10.12739/
  • Abstract Reading : 1431
  • Download : 161
  • Share :

  • PDF Download

Issue Details

  • Year : 2013
  • Volume : 8
  • Issue : 1
  • Number of Articles Published : 5
  • Published Date : 1.01.2013

Cover Download Context Page Download
Engineering Sciences

Serial Number : 1A
ISSN No. : 1308-7231
Release Interval (in a Year) : 4 Issues

BİNALARDA DIŞ DUVAR YALITIMININ HAVA KİRLİLİĞİ AÇISINDAN ÖNEMİ: BALIKESİR İL MERKEZİ ÖRNEĞİ

Okan KON 1

Ülkemiz toplam tüketilen enerjinin yaklaşık % 30`nu binaların ısıtılması ve soğutulması amacıyla kullanmaktadır. Yalıtımsız binalar nedeniyle fazla kullanılan enerji; kükürtdioksit, karbonmonoksit, karbondioksit, toz ve kül gibi maddeleri meydana getirir, bu ise hava kirliliğini arttırmaktadır. Bu kirletici maddelerin miktarı binalarda yalıtım uygulamaları sonucu azaltılabilir. Ülkemizde konutlarda enerji tasarrufuna yönelik, TS 825 "Binalarda Isı Yalıtım Kuralları"standardı en son 2008 yılında yenilenmiştir. Standarda ülkemiz 4 bölgeye ayrılmıştır. Bu çalışmada, TS 825 standardına göre 2. bölgede bulunan Balıkesir ili için yapılmıştır. Balıkesir il merkezinde ısıtma amaçlı doğal gaz tüketimi son 5 yılda hızlı bir şekilde artmıştır. Çalışmada, Balıkesir ilini temsil eden örnek bir bina seçilmiştir. Örnek binada doğal gaz ve kömürün ısıtma amaçlı yakıt olarak kullanıldığı kabul edilmiştir. Örnek binanın dış duvarlarında farklı kalınlıkta ve tipte yalıtım malzemeleri kullanılmıştır ve

Keywords
Konutlarda Yalıtım, Yalıtım Kalınlığı, Hava Kirliliği, Enerji Tasarrufu, Yakıt,

THE IMPORTANCE OF OUTER WALL INSULATION IN REGARDS TO AIR POLLUTION: EXAMPLE OF BALIKESIR CITY CENTER

Okan KON 1

In our country, approximately 30% of total consumed energy is used for heating and cooling of the buildings. Excessive energy used due to uninsulated buildings; produces materials like sulfur dioxide, carbon monoxide, carbon dioxide, dust and ash, which rises air pollution. Level of these pollutant can be decreased through the insulation applications for buildings. The TS 825, A Heat Insulation Rules for Buildings` standard is aimed at energy saving in residences in our country was last renewed in 2008. According to this standard our country is divided into 4 regions. This study is made for the city of Balıkesir which resides in the 2nd region with respect to the TS 825 standard. Natural gas consumption for heating purposes has increased rapidly in the last 5 years in the city center of Balıkesir. A sample building which represents the city of Balıkesir is chosen. Therefore, it is regarded as that natural gas and coal are used as fuel for heating purposes in the sample building.

Keywords
Insulation in Houses, Insulation Thickness, Air Pollution, Energy Saving, Fuel, Fuel,

Details
   

Authors

Okan KON (1) (Corresponding Author)

Balıkesir Üniversitesi
okankon76@yahoo.com

Supporting Institution

:

Project Number

:

Thanks

:
References