Technological Applied Sciences

Serial Number : 2A
ISSN No. : 1308-7223
Release Interval (in a Year) : 4 Issues

ÜÇ BOYUTLU ZEMİN-YAPI SİSTEMLERİNDE AKTİF YÖNTEMLERLE TİTREŞİM İZOLASYONU SAĞLANABİLİRLİĞİNİN ARAŞTIRILMASI

Oğuz Akın DÜZGÜN1 , AHMET ŞAHIN ZAIMOĞLU2

Bu çalışmada, dinamik yük etkisindeki üç boyutlu bir zemin yapı sisteminin dinamik davranışı ve zemin yüzeyinde açılan çukurların titreşim yalıtımı üzerindeki etkinliği parametrik olarak incelenmiştir. Modellemede ve analizlerde Plaxis 3D programından faydalanılmıştır. Çalışmada çukurun derinliği, genişliği, uzunluğu ve yeri parametre olarak seçilmiştir. Sonuçlar zemin yüzeyinde yer değiştirmeler cinsinden, yapıda da hem yer değiştirme hem de kesit tesiri cinsinden elde edilmiştir. Çalışmadan elde edilen sonuçlar titreşim yalıtımı için en etkili parametrenin çukurun derinliği olduğunu göstermektedir. Çukur derinliği arttıkça zemin yüzeyindeki ve yapıdaki titreşimler belirgin bir şekilde azalmaktadır. Titreşim yalıtımı problemlerindeki bir diğer etkin parametre de çukurun genişliğidir. Çukurun genişliğinin artması da genlikleri önemli ölçüde azaltmaktadır. Ancak bu azalım derinlik için elde edilen sonuçlardan daha küçüktür. Elde edilen sonuçlara göre çukurun uzunluğunun, yerinin ve içinin farklı malzemelerle doldurularak kullanılmasının titreşim yalıtımı çok az etkilediği sonucuna varılmıştır.

Keywords
Titreşim Yalıtımı , Zemin-Yapı Etkileşimi, Sonlu Elemanlar, Geçirgen Sınırlar, Çukur Geometrisi ,

THE INVESTIGATION OF VIBRATION ISOLATION IN THREE DIMENSIONAL SOIL-STRUCTURE SYSTEMS BY ACTIVE METHODS

Oğuz Akın DÜZGÜN1 , AHMET ŞAHIN ZAIMOĞLU2

In this study, dynamic response of a 3D soil-structure system and effectiveness of open trenches at soil surface on vibration isolation is investigated under dynamic load. In the modelling and analyzing Plaxis 3D computer program is used. Depth, width, length and location of the trench are chosen as parameters. The results obtained in the form of displacements, axial load, shear and bending moment. The results show that the most effective parameter on vibration isolation is the depth of the trench. As the trench depth increases, vibration amplitudes on both soil surface and structure systematically decrease. Another effective parameter in isolation problems is width of the trench. Increase in the width of the trench decreases amplitudes, significantly, but lesser than the results those of the trench depth. According to the results, length and location of the trench and filling the trench by different materials have minor effect on the vibration isolation.

Keywords
Vibration Isolation, Soil-Structure Interaction, Finite Elements, Transparent Boundaries, Geometry of Trench ,

Details
   

Authors

Oğuz Akın DÜZGÜN (1) (Corresponding Author)

ATATÜRK ÜNIVERSITESI
oaduzgun@atauni.edu.tr | 0000-0003-0842-9031

AHMET ŞAHIN ZAIMOĞLU (2)

zaimoglu@atauni.edu.tr | 0000-0001-5245-0212

Supporting Institution

:

Project Number

:

Thanks

:
References
[1] Kattis, S.E., Polyzos, D. and Beskos, D.E., (1999). Vibration Isolation by A Row of Piles Using A 3-D Frequency Domain BEM. International Journal for Numerical Methods in Engineering, Volume:46, pp:713–728.