YÜKSEK GERİLİM HATLARINDA KULLANILAN DEMET İLETKEN İÇİNDEKİ İLETKENLER ARASI MESAFENİN TAVLAMA BENZETİMİ KULLANILARAK BELİRLENMESİ

Salih TOSUN1 , Ali OZTURK 2 , Serhat DUMAN 3 , M.Ali Yalçın 4 , kenan döşoğlu 5

Yüksek gerilim hatlarında kullanılan demet iletken içindeki iletkenler arası mesafenin en uygun değerde olması gerekmektedir. Yüksek gerilim hatlarında korona kayıpları başladığında elektrik alanı maksimum olmakta ve matematiksel denklemlerin analizi ile hesaplanmaktadır. Bu çalışmada matematiksel denklemler ile demet iletken içindeki iletkenler arası mesafe nümerik analiz yöntemlerinden biri olan Gauss Seidel (GS) ve sezgisel metotlardan biri olan Tavlama Benzetimi (TB) kullanılarak belirlenmiştir. Her iki metot da bulunan sonuçlar karşılaştırılmıştır. Sonuçlara göre SA’ nın GS’ ye 220, 380 ve 500 kV değerlerinde sırasıyla %0.0117, %0.0012, %0,0061 daha iyi sonuçlar verdiği görülmüştür.

Keywords
Güç Sistemleri, Demet İletken, Optimizasyon, Tavlama Benzetimi, Gauss Seidel,

THE DETERMINATION OF THE DISTANCE BETWEEN THE CONDUCTORS IN BUNDLED CONDUCTOR USED IN HIGH VOLTAGE TRANSMISSION LINES BY USING SIMULATED ANNEALING

Salih TOSUN1 , Ali OZTURK 1 , Serhat DUMAN 1 , M.Ali Yalçın 1 , kenan döşoğlu 1

The most suitable value of distance between the conductors in bundled conductor is necessary that used in high voltage transmission lines. The maximum electric field when corona loss started in the high voltage line system was calculated by mathematical equation analysis. In this study, the distance between the conductors in bundled conductor have been determined by using Gauss Seidel (GS) of numeric analysis methods and Simulated Annealing (SA) of heuristic methods with mathematical equations. Results taken with both methods have been compared to each other. According to results of SA to GS, it has been seen the better %0.0117, % 0.0012, %0,0061, in 220, 380 and 500 kV values respectively.

Keywords
Power Systems, Bundled Conductor, Optimization, Simulated Annealing, Gauss Seidel,

Details
   

Authors

Salih TOSUN (1) (Corresponding Author)

Düzce Üniversitesi
salihtosun@duzce.edu.tr | 0000-0002-5698-6628

Ali OZTURK (2)

Düzce ÜNİVERSİTESİ
aliozturk@duzce.edu.tr

Serhat DUMAN (3)

Düzce Üniversitesi
serhatduman@duzce.edu.tr

M.Ali Yalçın (4)

salihtosun@hotmail.com

kenan döşoğlu (5)

kenandosoglu@duzce.edu.tr

Supporting Institution

:

Project Number

:

Thanks

:
References