• icon+90(533) 652 66 86
  • iconnwsa.akademi@hotmail.com
  • icon Fırat Akademi Samsun-Türkiye

Article Details

  • Article Code : NWSA-2628-1528
  • Article Type : Araştırma Makalesi
  • Publication Number : 1A0171
  • Page Number : 497-506
  • Doi : 10.12739/
  • Abstract Reading : 1328
  • Download : 187
  • Share :

  • PDF Download

Issue Details

  • Year : 2011
  • Volume : 6
  • Issue : 2
  • Number of Articles Published : 16
  • Published Date : 1.04.2011

Cover Download Context Page Download
Engineering Sciences

Serial Number : 1A
ISSN No. : 1308-7231
Release Interval (in a Year) : 4 Issues

SÜREKLİ TABLALI KİRİŞSİZ DÖŞEMELERİN DAVRANIŞINA BOYUTSAL PARAMETRELERİN ETKİSİ

Sibel SAĞLIYAN 1 , Ali Sayıl ERDOĞAN 2 , Muhammet KARATON3

Bu çalışmada, her iki doğrultuda eşit döşeme açıklığına sahip sürekli tablalı kirişsiz döşemeli bir betonarme kat çerçevesi incelenmiştir. Çözümlerde sonlu elemanlar yöntemi kullanılmıştır. Sonlu eleman ağ sisteminde bant-kiriş veya döşeme bandı olarak isimlendirilen sürekli tablalar, çerçeve eleman olarak ve döşemeler ise kabuk eleman olarak modellenmiştir. Ölü ve hareketli yükler altında kat çerçeve sisteminin doğrusal olmayan davranışı için toplanmış tip plastik mafsal modeli kullanılmıştır. Kat çerçevesinin, beton sınıfı, hesap açıklığı, sürekli tablaların genişlik ve yükseklikleri ile donatı oranları değiştirilerek toplamda 810 adet çözüm elde edilmiştir. Çözümlerden dış ve iç açıklıkların mesnet ve açıklık momentleri ile düşey yer değiştirme değerleri elde edilmiştir. Bu sonuçlar kullanılarak, STATISTICA programı yardımıyla, moment ve yer değiştirme değerlerine uygun fonksiyonlar elde edilmiştir. Tanımlanan bu fonksiyonlar ve eşdeğer çerçeve yöntemiyle elde edilen sonuçlar, sonlu elemanlar yöntemi sonuçlarıyla ayrı ayrı karşılaştırılmıştır.

Keywords
Bant kiriş, Sürekli tabla, Sonlu Elemanlar, Doğrusal olmayan analiz, İstatistiksel analiz,

THE EFFECT OF DIMENSIONAL PARAMETERS ON THE BEHAVIOUR OF REINFORCED CONCRETE SLABS WITH CONTINUOUS DROP PANEL

Sibel SAĞLIYAN 1 , Ali Sayıl ERDOĞAN 1 , Muhammet KARATON1

In this study, a reinforced concrete story frame with the slab with continuous drop panel in which slab span length was equal in two directions was investigated. In the finite element modeling, the thickened portions of the slab which was called band-beams or slab-bands were accepted as frame elements and slabs as shell elements. The lumped type plastic hinge model was used for the nonlinear behavior of the story frame system under the dead and live loads. In total, 810 solutions were performed on the story frame by modifying some properties, namely: the concrete strength, the span length, the width of continuous band-beam, the height of continuous band-beam and the percentage of steel reinforcement. The support moments, the span moments and span midpoint vertical deflections were calculated for the interior and the exterior spans. Using these results, several functions of the moment and deflection were obtained by using STATISTICA program. The results obtained using the equivalent fra

Keywords
Band beam, Continuous drop panel, Finite Elements, Non-linear analysis, Statistically analysis,

Details
   

Authors

Sibel SAĞLIYAN (1) (Corresponding Author)

ssagliyan@firat.edu.tr

Ali Sayıl ERDOĞAN (2)

Bingöl Üniversitesi Müh. ve Mim. Fak. Dekanı
aserdogan@firat.edu.tr

Muhammet KARATON (3)

mkaraton@msn.com

Supporting Institution

:

Project Number

:

Thanks

:
References